English Polish
Politechnika Morska w Szczecinie

DSpace Home

DSpace/Manakin Repository

Show simple item record

Author Sidun, Jarosław
Affiliation Bialystok University of Technology, Mechanical Faculty Department of Materials Science and Biomedical Engineering Politechnika Białostocka, Wydział Mechaniczny, Katedra Inżynierii Materiałowej i Technologii Maszyn 15-351 Białystok, ul. Wiejska 45c
E-mail jareks@pb.edu.pl
ISSN printed 1733-8670
URI https://repository.pm.szczecin.pl/handle/123456789/270
Abstract The internal fixation of maxillofacial fractures with plates and distracters has gained growing popularity during the last decades. The design of implants for fracture fixation has undergone a gradual evolution over the years as researchers have tried to facilitate healing and decrease the rate of complications. Osteolysis is one of the foremost problems limiting the survival of current implantation procedures. It is induced by the wear particles and corrosion products which incite an inflammatory response resulting in bone resorption and eventual loosening and failure of the bone fixation. The future research will help to limit the effects of wear particles by identifying the most suitable bearing surfaces. The pathologic cascade of events triggered by wear particles may be a potential site of action for drugs intended to prevent or check the progression of the disease. The paper presents a damages problems of the maxillofacial plate fixation. The surface failure at plate stabiliser elements showed typical damages for this system. Damages of screw’s steepl heads as well as the surface layers failure of the the coned seat on tie plates were observed. The surface failure at a screws were visible in a lesser degree. The biggest wear areas are visible on the cooperating surfaces of the plate sockets and the bone screw heads. Many types of damage characteristic of processes of corrosion damage and tribological wear, mainly abrasive, adhesive, and fretting wear, are observed here
Pages 88–92
Publisher Scientific Journals of the Maritime University of Szczecin, Zeszyty Naukowe Akademii Morskiej w Szczecinie
Keywords wear
Keywords exploitation
Keywords fretting
Keywords maxillofacial fixation
Title Evaluation of wear processes of titanium plates used for internal maxillofacial fixation
Type Original scientific article
References
  1. ZAFFE D., BERTOLDI C., KONSOLO U.: Accumulation of aluminium in lamer bone after implantation of titanum plater, Ti-6Al-4V screws, hydroxyapatite granules, Bioma-terials 2004, 25, 3837–3844.
  2. AGRAWAL S.: Osteolysis-basic science, incidence and diag-nosis. Current Orthopaedics 2004, 18, 220–231.
  3. HATTON P. V., BROOK I.M.: The role of electron micros-copy in the evaluation of biomaterials. European Micros-copy and Analysis 1998, January, 39–41.
  4. KRISCHAK G.D.,GEBHART F., MOHR W., KRIVAN V., IGNA-TIUK A., BECH A., WACHTER N.J., REUTER P., ARAND M., KINZL L., CLAUS L.E.: Diffrence in metallic weaar distribu-tion released from commercially pure titanium compared with stainless steel plates, arch Orthop Trauma Surg. 2004, 124, 104–113.
  5. VOGGENREITER G., LEITING S., BRAUER H., LEITING P., MAJETSCHAK M., BARDENHEUER M., OBERTACHE V.: Im-muno – inflammatory tissue reaction to stainless – steel and titanum plates used for internal of long bones, Biomaterials 2003, 24, 247–257.
  6. WINNER C., GLUCH H.: Aseptic Loosening After CD Instrumentation in the Treatment of Scoliosis: A Report about Eight Cases. Journal of Spinal Disorder 1998, 11, 440–443.
ISSN on-line 2392-0378
Language English
Funding No data
Figures 5
Tables 1
Published 2010-12-20
Accepted 2010-11-25
Recieved 2010-10-27


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search repository

Advanced Search

Browse

My Account

RSS Feeds